Active Filters

  • (-) Eawag Departments = Environmental Chemistry UCHEM
  • (-) Publication Year = 2006 - 2018
  • (-) Journal = Journal of Chromatography A
  • (-) Keywords ≠ environmental analysis
Search Results 1 - 6 of 6
  • RSS Feed
Select Page
Pixel-by-pixel correction of retention time shifts in chromatograms from comprehensive two-dimensional gas chromatography coupled to high resolution time-of-flight mass spectrometry
Zushi, Y., Gros, J., Tao, Q., Reichenbach, S. E., Hashimoto, S., & Arey, J. S. (2017). Pixel-by-pixel correction of retention time shifts in chromatograms from comprehensive two-dimensional gas chromatography coupled to high resolution time-of-flight mass spectrometry. Journal of Chromatography A, 1508, 121-129. https://doi.org/10.1016/j.chroma.2017.05.065
Retention projection enables accurate calculation of liquid chromatographic retention times across labs and methods
Abate-Pella, D., Freund, D. M., Ma, Y., Simón-Manso, Y., Hollender, J., Broeckling, C. D., … Boswell, P. G. (2015). Retention projection enables accurate calculation of liquid chromatographic retention times across labs and methods. Journal of Chromatography A, 1412, 43-51. https://doi.org/10.1016/j.chroma.2015.07.108
Analyte quantification with comprehensive two-dimensional gas chromatography: assessment of methods for baseline correction, peak delineation, and matrix effect elimination for real samples
Samanipour, S., Dimitriou-Christidis, P., Gros, J., Grange, A., & Arey, J. S. (2015). Analyte quantification with comprehensive two-dimensional gas chromatography: assessment of methods for baseline correction, peak delineation, and matrix effect elimination for real samples. Journal of Chromatography A, 1375, 123-139. https://doi.org/10.1016/j.chroma.2014.11.049
Multiresidue analysis of 88 polar organic micropollutants in ground, surface and wastewater using online mixed-bed multilayer solid-phase extraction coupled to high performance liquid chromatography-tandem mass spectrometry
Huntscha, S., Singer, H. P., McArdell, C. S., Frank, C. E., & Hollender, J. (2012). Multiresidue analysis of 88 polar organic micropollutants in ground, surface and wastewater using online mixed-bed multilayer solid-phase extraction coupled to high performance liquid chromatography-tandem mass spectrometry. Journal of Chromatography A, 1268, 74-83. https://doi.org/10.1016/j.chroma.2012.10.032
Comparison of two extraction methods for the analysis of per- and polyfluorinated chemicals in digested sewage sludge
Zhang, T., Sun, H., Gerecke, A. C., Kannan, K., Müller, C. E., & Alder, A. C. (2010). Comparison of two extraction methods for the analysis of per- and polyfluorinated chemicals in digested sewage sludge. Journal of Chromatography A, 1217(31), 5026-5034. https://doi.org/10.1016/j.chroma.2010.05.061
Challenge of high polarity and low concentrations in analysis of cytostatics and metabolites in wastewater by hydrophilic interaction chromatography/tandem mass spectrometry
Kovalova, L., McArdell, C. S., & Hollender, J. (2009). Challenge of high polarity and low concentrations in analysis of cytostatics and metabolites in wastewater by hydrophilic interaction chromatography/tandem mass spectrometry. Journal of Chromatography A, 1216(7), 1100-1108. https://doi.org/10.1016/j.chroma.2008.12.028