Active Filters

  • (-) Empa Authors = Affolter, Christian
Search Results 1 - 20 of 41
Select Page
Ductile compressive behavior of biomedical alloys
Affolter, C., Thorwarth, G., Arabi-Hashemi, A., Müller, U., & Weisse, B. (2020). Ductile compressive behavior of biomedical alloys. Metals, 10(1), 60 (11 pp.). https://doi.org/10.3390/met10010060
Estimating lumbar passive stiffness behaviour from subject-specific finite element models and in vivo 6DOF kinematics
Affolter, C., Kedzierska, J., Vielma, T., Weisse, B., & Aiyangar, A. (2020). Estimating lumbar passive stiffness behaviour from subject-specific finite element models and in vivo 6DOF kinematics. Journal of Biomechanics, 102, 109681 (11 pp.). https://doi.org/10.1016/j.jbiomech.2020.109681
Testing strategies and failure modes of dimpled laminate plates
Affolter, C., Barbezat, M., Piskoty, G., Steger, R., & Terrasi, G. (2019). Testing strategies and failure modes of dimpled laminate plates. Engineering Failure Analysis, 101, 283-297. https://doi.org/10.1016/j.engfailanal.2019.03.011
Failure of a sag water pipe triggered by aging of the GFRP composite relining?
Affolter, C., Barbezat, M., Piskoty, G., Neuner, O., & Terrasi, G. (2018). Failure of a sag water pipe triggered by aging of the GFRP composite relining. Engineering Failure Analysis, 84, 358-370. https://doi.org/10.1016/j.engfailanal.2017.09.017
A water-responsive, gelatine-based human skin model
Dąbrowska, A., Rotaru, G. M., Spano, F., Affolter, C., Fortunato, G., Lehmann, S., … Rossi, R. M. (2017). A water-responsive, gelatine-based human skin model. Tribology International, 113, 316-322. https://doi.org/10.1016/j.triboint.2017.01.027
Failure analysis of a ropeway accident focussing on the wire rope's fracture load under lateral pressure
Piskoty, G., Affolter, C., Sauder, M., Nambiar, M., & Weisse, B. (2017). Failure analysis of a ropeway accident focussing on the wire rope's fracture load under lateral pressure. Engineering Failure Analysis, 82, 648-656. https://doi.org/10.1016/j.engfailanal.2017.05.003
Compressive testing of ductile high-strength alloys
Affolter, C., Müller, U., Leinenbach, C., & Weisse, B. (2015). Compressive testing of ductile high-strength alloys. Journal of Testing and Evaluation, 43(6), 1554-1562. https://doi.org/10.1520/JTE20140301
Limitations of analytical strength verifications with local effects and nonlinearities: A case study on a failed high rack rail
Affolter, C., Piskoty, G., Koller, R. E., Gfeller, U., & Terrasi, G. P. (2015). Limitations of analytical strength verifications with local effects and nonlinearities: A case study on a failed high rack rail. Engineering Failure Analysis, 56, 28-38. https://doi.org/10.1016/j.engfailanal.2015.05.002
Aquacasting—a new shaping concept for water based reactive tape casting
Durif, C., Frömder, C., Affolter, C., Lippmann, W., & Graule, T. (2015). Aquacasting—a new shaping concept for water based reactive tape casting. Journal of the European Ceramic Society, 35(13), 3633-3640. https://doi.org/10.1016/j.jeurceramsoc.2015.04.029
Long-term bending creep behavior of thin-walled CFRP tendon pretensioned spun concrete poles
Terrasi, G. P., Meier, U., & Affolter, C. (2014). Long-term bending creep behavior of thin-walled CFRP tendon pretensioned spun concrete poles. Polymers, 6(7), 2065-2081. https://doi.org/10.3390/polym6072065
Are asymmetric metal markings on the cone surface of ceramic femoral heads an indication of entrapped debris?
Valet, S., Weisse, B., Kuebler, J., Zimmermann, M., Affolter, C., & Terrasi, G. P. (2014). Are asymmetric metal markings on the cone surface of ceramic femoral heads an indication of entrapped debris? BioMedical Engineering OnLine, 13(1), 38 (22 pp.). https://doi.org/10.1186/1475-925X-13-38
Design and characterization of a bicomponent melt-spun fiber optimized for artificial turf applications
Hufenus, R., Affolter, C., Camenzind, M., & Reifler, F. A. (2013). Design and characterization of a bicomponent melt-spun fiber optimized for artificial turf applications. Macromolecular Materials and Engineering, 298(6), 653-663. https://doi.org/10.1002/mame.201200088
Fatigue and cyclic deformation behavior of brazed steel joints
Koster, M., Kenel, C., Stutz, A., Lee, W. J., Lis, A., Affolter, C., & Leinenbach, C. (2013). Fatigue and cyclic deformation behavior of brazed steel joints. Materials Science and Engineering A: Structural Materials: Properties, Microstructure and Processing, 581, 90-97. https://doi.org/10.1016/j.msea.2013.05.083
Accident caused by dynamic overloading of a ship mooring rope
Valet, S., Piskoty, G., Michel, S., Affolter, C., & Beer, M. (2013). Accident caused by dynamic overloading of a ship mooring rope. Engineering Failure Analysis, 35, 439-453. https://doi.org/10.1016/j.engfailanal.2013.03.027
Retrospective lifetime estimation of failed and explanted diamond-like carbon coated hip joint balls
Hauert, R., Falub, C. V., Thorwarth, G., Thorwarth, K., Affolter, C., Stiefel, M., … Taeger, G. (2012). Retrospective lifetime estimation of failed and explanted diamond-like carbon coated hip joint balls. Acta Biomaterialia, 8(8), 3170-3176. https://doi.org/10.1016/j.actbio.2012.04.016
Fire behavior of thin CFRP pretensioned high-strength concrete slabs
Terrasi, G. P., Bisby, L., Barbezat, M., Affolter, C., & Hugi, E. (2012). Fire behavior of thin CFRP pretensioned high-strength concrete slabs. Journal of Composites for Construction, 16(4), 381-394. https://doi.org/10.1061/(ASCE)CC.1943-5614.0000271
Determination of the translational and rotational stiffnesses of an L4–L5 functional spinal unit using a specimen-specific finite element model
Weisse, B., Aiyangar, A. K., Affolter, C., Gander, R., Terrasi, G. P., & Ploeg, H. (2012). Determination of the translational and rotational stiffnesses of an L4–L5 functional spinal unit using a specimen-specific finite element model. Journal of the Mechanical Behavior of Biomedical Materials, 13, 45-61. https://doi.org/10.1016/j.jmbbm.2012.04.002
Failure of a bus hoisting platform due to unexpected system behaviour
Affolter, C., Piskoty, G., & Weisse, B. (2011). Failure of a bus hoisting platform due to unexpected system behaviour. Engineering Failure Analysis, 18(7), 1742-1749. https://doi.org/10.1016/j.engfailanal.2011.03.025
Numerical optimization of a compact and reusable pretensioning anchorage system for CFRP tendons
Terrasi, G. P., Affolter, C., & Barbezat, M. (2011). Numerical optimization of a compact and reusable pretensioning anchorage system for CFRP tendons. Journal of Composites for Construction, 15(2), 126-135. https://doi.org/10.1061/(ASCE)CC.1943-5614.0000080
Bicomponent artificial turf fibers for future sports flooring
Hufenus, R., Affolter, C., Camenzind, M., Halbeisen, M., Spierings, A., Tischhauser, A., … Schramm, G. (2010). Bicomponent artificial turf fibers for future sports flooring (pp. 117-118). Presented at the Fiber society 2010 spring conference. .