Active Filters

  • (-) PSI Authors = Weber, Damien C.
Search Results 1 - 20 of 154

Pages

  • RSS Feed
Select Page
An approach for estimating dosimetric uncertainties in deformable dose accumulation in pencil beam scanning proton therapy for lung cancer
Amstutz, F., Nenoff, L., Albertini, F., Ribeiro, C. O., Knopf, A. C., Unkelbach, J., … Zhang, Y. (2021). An approach for estimating dosimetric uncertainties in deformable dose accumulation in pencil beam scanning proton therapy for lung cancer. Physics in Medicine and Biology, 66(10), 105007 (12 pp.). https://doi.org/10.1088/1361-6560/abf8f5
Al<sub>2</sub>O<sub>3</sub>:C optically stimulated luminescence dosimeters (OSLDs) for ultra-high dose rate proton dosimetry
Christensen, J. B., Togno, M., Nesteruk, K. P., Psoroulas, S., Meer, D., Weber, D. C., … Safai, S. (2021). Al2O3:C optically stimulated luminescence dosimeters (OSLDs) for ultra-high dose rate proton dosimetry. Physics in Medicine and Biology, 66(8), 085003 (11 pp.). https://doi.org/10.1088/1361-6560/abe554
ESTRO ACROP guideline for target volume delineation of skull base tumors
Combs, S. E., Baumert, B. G., Bendszus, M., Bozzao, A., Brada, M., Fariselli, L., … Minniti, G. (2021). ESTRO ACROP guideline for target volume delineation of skull base tumors. Radiotherapy and Oncology, 156, 80-94. https://doi.org/10.1016/j.radonc.2020.11.014
Enhanced-deep-inspiration breath hold superior to high-frequency percussive ventilation for respiratory motion mitigation: a physiology-driven, MRI-guided assessment towards optimized lung cancer treatment with proton therapy
Emert, F., Missimer, J., Eichenberger, P. A., Walser, M., Gmür, C., Lomax, A. J., … Spengler, C. M. (2021). Enhanced-deep-inspiration breath hold superior to high-frequency percussive ventilation for respiratory motion mitigation: a physiology-driven, MRI-guided assessment towards optimized lung cancer treatment with proton therapy. Frontiers in Oncology, 11, 621350 (17 pp.). https://doi.org/10.3389/fonc.2021.621350
Technical assessment of the NDI Polaris Vega optical tracking system
Fattori, G., Lomax, A. J., Weber, D. C., & Safai, S. (2021). Technical assessment of the NDI Polaris Vega optical tracking system. Radiation Oncology, 16(1), 87 (4 pp.). https://doi.org/10.1186/s13014-021-01804-7
Liver-ultrasound-guided lung tumour tracking for scanned proton therapy: a feasibility study
Krieger, M., Giger, A., Jud, C., Duetschler, A., Salomir, R., Bieri, O., … Zhang, Y. (2021). Liver-ultrasound-guided lung tumour tracking for scanned proton therapy: a feasibility study. Physics in Medicine and Biology, 66(3), 035011 (14 pp.). https://doi.org/10.1088/1361-6560/abcde6
Combining clinical and dosimetric features in a PBS proton therapy cohort to develop a NTCP model for radiation-induced optic neuropathy
Köthe, A., van Luijk, P., Safai, S., Kountouri, M., Lomax, A. J., Weber, D. C., & Fattori, G. (2021). Combining clinical and dosimetric features in a PBS proton therapy cohort to develop a NTCP model for radiation-induced optic neuropathy. International Journal of Radiation Oncology Biology Physics, 110(2), 587-595. https://doi.org/10.1016/j.ijrobp.2020.12.052
Dosimetric influence of deformable image registration uncertainties on propagated structures for online daily adaptive proton therapy of lung cancer patients
Nenoff, L., Matter, M., Amaya, E. J., Josipovic, M., Knopf, A. C., Lomax, A. J., … Albertini, F. (2021). Dosimetric influence of deformable image registration uncertainties on propagated structures for online daily adaptive proton therapy of lung cancer patients. Radiotherapy and Oncology, 159, 136-143. https://doi.org/10.1016/j.radonc.2021.03.021
Commissioning of a clinical pencil beam scanning proton therapy unit for ultra-high dose rates (FLASH)
Nesteruk, K. P., Togno, M., Grossmann, M., Lomax, A. J., Weber, D. C., Schippers, J. M., … Psoroulas, S. (2021). Commissioning of a clinical pencil beam scanning proton therapy unit for ultra-high dose rates (FLASH). Medical Physics. https://doi.org/10.1002/mp.14933
Effects of deep inspiration breath hold on prone photon or proton irradiation of breast and regional lymph nodes
Speleers, B., Schoepen, M., Belosi, F., Vakaet, V., De Neve, W., Deseyne, P., … De Gersem, W. (2021). Effects of deep inspiration breath hold on prone photon or proton irradiation of breast and regional lymph nodes. Scientific Reports, 11(1), 6085 (11 pp.). https://doi.org/10.1038/s41598-021-85401-4
Quality assurance of radiotherapy in the ongoing EORTC 1420 "Best of" trial for early stage oropharyngeal, supraglottic and hypopharyngeal carcinoma: results of the benchmark case procedure
Stelmes, J. J., Vu, E., Grégoire, V., Simon, C., Clementel, E., Kazmierska, J., … Weber, D. C. (2021). Quality assurance of radiotherapy in the ongoing EORTC 1420 "Best of" trial for early stage oropharyngeal, supraglottic and hypopharyngeal carcinoma: results of the benchmark case procedure. Radiation Oncology, 16(1), 81 (10 pp.). https://doi.org/10.1186/s13014-021-01809-2
Potential and pitfalls of 1.5T MRI imaging for target volume definition in ocular proton therapy
Via, R., Hennings, F., Pica, A., Fattori, G., Beer, J., Peroni, M., … Hrbacek, J. (2021). Potential and pitfalls of 1.5T MRI imaging for target volume definition in ocular proton therapy. Radiotherapy and Oncology, 154, 53-59. https://doi.org/10.1016/j.radonc.2020.08.023
Dosimetric analysis of local failures in skull-base chordoma and chondrosarcoma following pencil beam scanning proton therapy
Basler, L., Poel, R., Schröder, C., Bolsi, A., Lomax, A., Tanadini-Lang, S., … Weber, D. C. (2020). Dosimetric analysis of local failures in skull-base chordoma and chondrosarcoma following pencil beam scanning proton therapy. Radiation Oncology, 15(1), 266 (10 pp.). https://doi.org/10.1186/s13014-020-01711-3
Outcomes, prognostic factors and salvage treatment for recurrent chordoma after pencil beam scanning proton therapy at the Paul Scherrer Institute
Beer, J., Kountouri, M., Kole, A. J., Murray, F. R., Leiser, D., Kliebsch, U., … Weber, D. C. (2020). Outcomes, prognostic factors and salvage treatment for recurrent chordoma after pencil beam scanning proton therapy at the Paul Scherrer Institute. Clinical Oncology, 32(8), 537-544. https://doi.org/10.1016/j.clon.2020.03.002
Pencil beam scanning proton therapy for the treatment of craniopharyngioma complicated with radiation-induced cerebral vasculopathies: a dosimetric and linear energy transfer (LET) evaluation
Bolsi, A., Placidi, L., Pica, A., Ahlhelm, F. J., Walser, M., Lomax, A. J., & Weber, D. C. (2020). Pencil beam scanning proton therapy for the treatment of craniopharyngioma complicated with radiation-induced cerebral vasculopathies: a dosimetric and linear energy transfer (LET) evaluation. Radiotherapy and Oncology, 149, 197-204. https://doi.org/10.1016/j.radonc.2020.04.052
Anthropomorphic phantom for deformable lung and liver CT and MR imaging for radiotherapy
Colvill, E., Krieger, M., Bosshard, P., Steinacher, P., Rohrer Schnidrig, B. A., Parkel, T., … Fattori, G. (2020). Anthropomorphic phantom for deformable lung and liver CT and MR imaging for radiotherapy. Physics in Medicine and Biology, 65(7), 07NT02 (10 pp.). https://doi.org/10.1088/1361-6560/ab7508
Role of complex networks for integrating medical images and radiomic features of intracranial ependymoma patients in response to proton radiotherapy
Dominietto, M., Pica, A., Safai, S., Lomax, A. J., Weber, D. C., & Capobianco, E. (2020). Role of complex networks for integrating medical images and radiomic features of intracranial ependymoma patients in response to proton radiotherapy. Frontiers in Medicine, 6, 333 (13 pp.). https://doi.org/10.3389/fmed.2019.00333
Commissioning and quality assurance of a novel solution for respiratory-gated PBS proton therapy based on optical tracking of surface markers
Fattori, G., Hrbacek, J., Regele, H., Bula, C., Mayor, A., Danuser, S., … Safai, S. (2020). Commissioning and quality assurance of a novel solution for respiratory-gated PBS proton therapy based on optical tracking of surface markers. Zeitschrift für Medizinische Physik. https://doi.org/10.1016/j.zemedi.2020.07.001
The potential of Gantry beamline large momentum acceptance for real time tumour tracking in pencil beam scanning proton therapy
Fattori, G., Zhang, Y., Meer, D., Weber, D. C., Lomax, A. J., & Safai, S. (2020). The potential of Gantry beamline large momentum acceptance for real time tumour tracking in pencil beam scanning proton therapy. Scientific Reports, 10(1), 15325 (13 pp.). https://doi.org/10.1038/s41598-020-71821-1
Liver-ultrasound based motion modelling to estimate 4D dose distributions for lung tumours in scanned proton therapy
Giger, A., Krieger, M., Jud, C., Duetschler, A., Salomir, R., Bieri, O., … Cattin, P. C. (2020). Liver-ultrasound based motion modelling to estimate 4D dose distributions for lung tumours in scanned proton therapy. Physics in Medicine and Biology, 65(23), 235050 (12 pp.). https://doi.org/10.1088/1361-6560/abaa26
 

Pages