Active Filters

  • (-) PSI Groups = 1702 Medical Physics
Search Results 1 - 20 of 49
Select Page
Mapping motion from 4D-MRI to 3D-CT for use in 4D dose calculations: a technical feasibility study
Boye, D., Lomax, T., & Knopf, A. (2013). Mapping motion from 4D-MRI to 3D-CT for use in 4D dose calculations: a technical feasibility study. Medical Physics, 40(6), 061702 (11 pp.). https://doi.org/10.1118/1.4801914
Population based modeling of respiratory lung motion and prediction from partial information
Boye, D., Samei, G., Schmidt, J., Székely, G., & Tanner, C. (2013). Population based modeling of respiratory lung motion and prediction from partial information. Progress in biomedical optics and imaging - proceedings of SPIE: Vol. 8669. (p. 86690U). Presented at the Medical imaging 2013: image processing. https://doi.org/10.1117/12.2007076
Adequate margin definition for scanned particle therapy in the incidence of intrafractional motion
Knopf, A. C., Boye, D., Lomax, A., & Mori, S. (2013). Adequate margin definition for scanned particle therapy in the incidence of intrafractional motion. Physics in Medicine and Biology, 58(17), 6079-6094. https://doi.org/10.1088/0031-9155/58/17/6079
Deformable motion reconstruction for scanned proton beam therapy using on-line x-ray imaging
Zhang, Y., Knopf, A., Tanner, C., Boye, D., & Lomax, A. J. (2013). Deformable motion reconstruction for scanned proton beam therapy using on-line x-ray imaging. Physics in Medicine and Biology, 58(24), 8621-8645. https://doi.org/10.1088/0031-9155/58/24/8621
Temporal lobe toxicity analysis after proton radiation therapy for skull base tumors
Pehlivan, B., Ares, C., Lomax, A. J., Stadelmann, O., Goitein, G., Timmermann, B., … Hug, E. B. (2012). Temporal lobe toxicity analysis after proton radiation therapy for skull base tumors. International Journal of Radiation Oncology Biology Physics, 83(5), 1432-1440. https://doi.org/10.1016/j.ijrobp.2011.10.042
Spot scanning-based proton therapy for intracranial meningioma: long-term results from the Paul Scherrer Institute
Weber, D. C., Schneider, R., Goitein, G., Koch, T., Ares, C., Geismar, J. H., … Hug, E. B. (2012). Spot scanning-based proton therapy for intracranial meningioma: long-term results from the Paul Scherrer Institute. International Journal of Radiation Oncology Biology Physics, 83(3), 865-871. https://doi.org/10.1016/j.ijrobp.2011.08.027
Respiratory liver motion estimation and its effect on scanned proton beam therapy
Zhang, Y., Boye, D., Tanner, C., Lomax, A. J., & Knopf, A. (2012). Respiratory liver motion estimation and its effect on scanned proton beam therapy. Physics in Medicine and Biology, 57(7), 1779-1795. https://doi.org/10.1088/0031-9155/57/7/1779
Experimental verification of IMPT treatment plans in an anthropomorphic phantom in the presence of delivery uncertainties
Albertini, F., Casiraghi, M., Lorentini, S., Rombi, B., & Lomax, A. J. (2011). Experimental verification of IMPT treatment plans in an anthropomorphic phantom in the presence of delivery uncertainties. Physics in Medicine and Biology, 56(14), 4415-4431. https://doi.org/10.1088/0031-9155/56/14/012
Is it necessary to plan with safety margins for actively scanned proton therapy?
Albertini, F., Hug, E. B., & Lomax, A. J. (2011). Is it necessary to plan with safety margins for actively scanned proton therapy? Physics in Medicine and Biology, 56(14), 4399-4413. https://doi.org/10.1088/0031-9155/56/14/011
Uncertainties and correction methods when modeling passive scattering proton therapy treatment heads with Monte Carlo
Bednarz, B., Lu, H. M., Engelsman, M., & Paganetti, H. (2011). Uncertainties and correction methods when modeling passive scattering proton therapy treatment heads with Monte Carlo. Physics in Medicine and Biology, 56(9), 2837-2854. https://doi.org/10.1088/0031-9155/56/9/013
Variations in linear energy transfer within clinical proton therapy fields and the potential for biological treatment planning
Grassberger, C., Trofimov, A., Lomax, A., & Paganetti, H. (2011). Variations in linear energy transfer within clinical proton therapy fields and the potential for biological treatment planning. International Journal of Radiation Oncology Biology Physics, 80(5), 1559-1566. https://doi.org/10.1016/j.ijrobp.2010.10.027
Accuracy of proton beam range verification using post-treatment positron emission tomography/computed tomography as function of treatment site
Knopf, A. C., Parodi, K., Paganetti, H., Bortfeld, T., Daartz, J., Engelsman, M., … Shih, H. (2011). Accuracy of proton beam range verification using post-treatment positron emission tomography/computed tomography as function of treatment site. International Journal of Radiation Oncology Biology Physics, 79(1), 297-304. https://doi.org/10.1016/j.ijrobp.2010.02.017
Scanned proton radiotherapy for mobile targets - the effectiveness of re-scanning in the context of different treatment planning approaches and for different motion characteristics
Knopf, A. C., Hong, T. S., & Lomax, A. (2011). Scanned proton radiotherapy for mobile targets - the effectiveness of re-scanning in the context of different treatment planning approaches and for different motion characteristics. Physics in Medicine and Biology, 56(22), 7257-7271. https://doi.org/10.1088/0031-9155/56/22/016
Emerging technologies in proton therapy
Schippers, J. M., & Lomax, A. J. (2011). Emerging technologies in proton therapy. Acta Oncologica, 50(6), 838-850. https://doi.org/10.3109/0284186X.2011.582513
A rapid communication from the AAPM Task Group 201: recommendations for the QA of external beam radiotherapy data transfer. AAPM TG 201: quality assurance of external beam radiotherapy data transfer
Siochi, R. A., Balter, P., Bloch, C. D., Santanam, L., Blodgett, K., Curran, B. H., … Zhu, X. R. (2011). A rapid communication from the AAPM Task Group 201: recommendations for the QA of external beam radiotherapy data transfer. AAPM TG 201: quality assurance of external beam radiotherapy data transfer. Journal of Applied Clinical Medical Physics, 12(1), 170-181. https://doi.org/10.1120/jacmp.v12i1.3479
Spot-scanning-based proton therapy for extracranial chordoma
Staab, A., Rutz, H. P., Ares, C., Timmermann, B., Schneider, R., Bolsi, A., … Hug, E. (2011). Spot-scanning-based proton therapy for extracranial chordoma. International Journal of Radiation Oncology Biology Physics, 81(4), e489-e496. https://doi.org/10.1016/j.ijrobp.2011.02.018
Helical tomotherapy vs. intensity-modulated proton therapy for whole pelvis irradiation in high-risk prostate cancer patients: dosimetric, normal tissue complication probability, and generalized equivalent uniform dose analysis
Widesott, L., Pierelli, A., Fiorino, C., Lomax, A. J., Amichetti, M., Cozzarini, C., … Schwarz, M. (2011). Helical tomotherapy vs. intensity-modulated proton therapy for whole pelvis irradiation in high-risk prostate cancer patients: dosimetric, normal tissue complication probability, and generalized equivalent uniform dose analysis. International Journal of Radiation Oncology Biology Physics, 80(5), 1589-1600. https://doi.org/10.1016/j.ijrobp.2010.10.005
Potential benefits of scanned intensity-modulated proton therapy versus advanced photon therapy with regard to sparing of the salivary glands in oropharyngeal cancer
van de Water, T. A., Lomax, A. J., Bijl, H. P., de Jong, M. E., Schilstra, C., Hug, E. B., & Langendijk, J. A. (2011). Potential benefits of scanned intensity-modulated proton therapy versus advanced photon therapy with regard to sparing of the salivary glands in oropharyngeal cancer. International Journal of Radiation Oncology Biology Physics, 79(4), 1216-1224. https://doi.org/10.1016/j.ijrobp.2010.05.012
The influence of the optimization starting conditions on the robustness of intensity-modulated proton therapy plans
Albertini, F., Hug, E. B., & Lomax, A. J. (2010). The influence of the optimization starting conditions on the robustness of intensity-modulated proton therapy plans. Physics in Medicine and Biology, 55(10), 2863-2878. https://doi.org/10.1088/0031-9155/55/10/005
Special report: workshop on 4D-treatment planning in actively scanned particle therapy-Recommendations, technical challenges, and future research directions
Knopf, A., Bert, C., Heath, E., Nill, S., Kraus, K., Richter, D., … Lomax, A. (2010). Special report: workshop on 4D-treatment planning in actively scanned particle therapy-Recommendations, technical challenges, and future research directions. Medical Physics, 37(9), 4608-4614. https://doi.org/10.1118/1.3475944