Active Filters

  • (-) PSI Groups = 3205 Electronics for Measuring Systems
  • (-) Publication Status = Published
Search Results 1 - 20 of 133

Pages

  • RSS Feed
Select Page
Quantum efficiency measurement and modeling of silicon sensors optimized for soft X-ray detection
Carulla, M., Barten, R., Baruffaldi, F., Bergamaschi, A., Borghi, G., Boscardin, M., … Zhang, J. (2024). Quantum efficiency measurement and modeling of silicon sensors optimized for soft X-ray detection. Sensors, 24(3), 942 (19 pp.). https://doi.org/10.3390/s24030942
Balancing gain and dynamic range in a 25 µm pitch hybrid pixel detector
Heymes, J., Barten, R., Baruffaldi, F., Bergamaschi, A., Brückner, M., Carulla, M., … Zhang, J. (2024). Balancing gain and dynamic range in a 25 µm pitch hybrid pixel detector. Journal of Instrumentation, 19(01), C01012 (9 pp.). https://doi.org/10.1088/1748-0221/19/01/C01012
Resolving soft X-ray photons with a high-rate hybrid pixel detector
Hinger, V., Barten, R., Baruffaldi, F., Bergamaschi, A., Borghi, G., Boscardin, M., … Zhang, J. (2024). Resolving soft X-ray photons with a high-rate hybrid pixel detector. Frontiers in Physics, 12, 1352134 (10 pp.). https://doi.org/10.3389/fphy.2024.1352134
Evaluation of HPK <em>n<sup>+</sup></em>-<em>p</em> planar pixel sensors for the CMS Phase-2 upgrade
Adam, W., Bergauer, T., Damanakis, K., Dragicevic, M., Frühwirth, R., Steininger, H., … Johns, W. (2023). Evaluation of HPK n+-p planar pixel sensors for the CMS Phase-2 upgrade. Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1053, 168326 (18 pp.). https://doi.org/10.1016/j.nima.2023.168326
Test beam performance of a CBC3-based mini-module for the phase-2 CMS outer tracker before and after neutron irradiation
Adam, W., Bergauer, T., Damanakis, K., Dragicevic, M., Frühwirth, R., Steininger, H., … Poudyal, N. (2023). Test beam performance of a CBC3-based mini-module for the phase-2 CMS outer tracker before and after neutron irradiation. Journal of Instrumentation, 18(4), P04001 (38 pp.). https://doi.org/10.1088/1748-0221/18/04/P04001
Study of the internal quantum efficiency of FBK sensors with optimized entrance windows
Carulla, M., Centis Vignali, M., Barten, R., Baruffaldi, F., Bergamaschi, A., Borghi, G., … Zhang, J. (2023). Study of the internal quantum efficiency of FBK sensors with optimized entrance windows. Journal of Instrumentation, 18, C01073 (11 pp.). https://doi.org/10.1088/1748-0221/18/01/C01073
Beam monitoring detectors for High Intensity Muon Beams
Dal Maso, G., Barchetti, F., Francesconi, M., Galli, L., Greuter, U., Hildebrandt, M., … Papa, A. (2023). Beam monitoring detectors for High Intensity Muon Beams. Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1047, 167739 (2 pp.). https://doi.org/10.1016/j.nima.2022.167739
The WaveDAQ integrated trigger and data acquisition system for the MEG II experiment
Francesconi, M., Baldini, A., Benmansour, H., Cei, F., Chiappini, M., Chiarello, G., … Vitali, B. (2023). The WaveDAQ integrated trigger and data acquisition system for the MEG II experiment. Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1045, 167542 (4 pp.). https://doi.org/10.1016/j.nima.2022.167542
The trigger system for the MEG II experiment
Francesconi, M., Baldini, A. M., Ban, S., Benmansour, H., Cattaneo, P. W., Cei, F., … Yoshida, K. (2023). The trigger system for the MEG II experiment. Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1046, 167736 (4 pp.). https://doi.org/10.1016/j.nima.2022.167736
Commissioning of the novel continuous angle multi-energy analysis spectrometer at the Paul Scherrer Institut
Lass, J., Jacobsen, H., Krighaar, K. M. L., Graf, D., Groitl, F., Herzog, F., … Mazzone, D. G. (2023). Commissioning of the novel continuous angle multi-energy analysis spectrometer at the Paul Scherrer Institut. Review of Scientific Instruments, 94(2), 023302 (9 pp.). https://doi.org/10.1063/5.0128226
Characterization of iLGADs using soft X-rays
Liguori, A., Barten, R., Baruffaldi, F., Bergamaschi, A., Borghi, G., Boscardin, M., … Zhang, J. (2023). Characterization of iLGADs using soft X-rays. Journal of Instrumentation, 18(12), P12006 (15 pp.). https://doi.org/10.1088/1748-0221/18/12/P12006
Towards large calorimeters based on Lanthanum Bromide or LYSO crystals coupled to silicon photomultipliers: a first direct comparison for future precision physics
Papa, A., Schwendimann, P., Baldini, A. M., Benmansour, H., Cei, F., Chiappini, M., … Vitali, B. (2023). Towards large calorimeters based on Lanthanum Bromide or LYSO crystals coupled to silicon photomultipliers: a first direct comparison for future precision physics. Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1049, 167997 (3 pp.). https://doi.org/10.1016/j.nima.2022.167997
Beam test performance of a prototype module with Short Strip ASICs for the CMS HL-LHC tracker upgrade
Adam, W., Bergauer, T., Damanakis, K., Dragicevic, M., Frühwirth, R., Steininger, H., … Johns, W. (2022). Beam test performance of a prototype module with Short Strip ASICs for the CMS HL-LHC tracker upgrade. Journal of Instrumentation, 17(6), P06039 (25 pp.). https://doi.org/10.1088/1748-0221/17/06/P06039
First demonstration of on-chip interpolation using a single photon counting microstrip detector
Bergamaschi, A., Andrä, M., Barten, R., Baruffaldi, F., Brückner, M., Carulla, M., … Zhang, J. (2022). First demonstration of on-chip interpolation using a single photon counting microstrip detector. Journal of Instrumentation, 17(11), C11012 (9 pp.). https://doi.org/10.1088/1748-0221/17/11/C11012
High-spatial resolution measurements with a GaAs:Cr sensor using the charge integrating MÖNCH detector with a pixel pitch of 25 μm
Chiriotti, S., Barten, R., Bergamaschi, A., Brückner, M., Carulla, M., Chsherbakov, I., … Zhang, J. (2022). High-spatial resolution measurements with a GaAs:Cr sensor using the charge integrating MÖNCH detector with a pixel pitch of 25 μm. Journal of Instrumentation, 17, P04007 (17 pp.). https://doi.org/10.1088/1748-0221/17/04/P04007
Detection of MeV electrons using a charge integrating hybrid pixel detector
Fröjdh, E., Baruffaldi, F., Bergamaschi, A., Carulla, M., Dinapoli, R., Greiffenberg, D., … Zhang, J. (2022). Detection of MeV electrons using a charge integrating hybrid pixel detector. Journal of Instrumentation, 17(12), C12004 (8 pp.). https://doi.org/10.1088/1748-0221/17/12/C12004
Advancing the JUNGFRAU detector toward low-energy X-ray applications
Hinger, V., al Haddad, A., Barten, R., Bergamaschi, A., Brückner, M., Carulla, M., … Zhang, J. (2022). Advancing the JUNGFRAU detector toward low-energy X-ray applications. Journal of Instrumentation, 17(9), C09027 (7 pp.). https://doi.org/10.1088/1748-0221/17/09/C09027
Observation of radiation damage in CdTe Schottky sensors created by 20 keV photons
Meyer, M., Andrä, M., Barten, R., Bergamaschi, A., Brückner, M., Busca, P., … Zhang, J. (2022). Observation of radiation damage in CdTe Schottky sensors created by 20 keV photons. Journal of Instrumentation, 17(6), P06035 (22 pp.). https://doi.org/10.1088/1748-0221/17/06/P06035
Calibration methods for charge integrating detectors
Mezza, D., Becker, J., Carraresi, L., Castoldi, A., Dinapoli, R., Goettlicher, P., … Zimmer, M. (2022). Calibration methods for charge integrating detectors. Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1024, 166078 (20 pp.). https://doi.org/10.1016/j.nima.2021.166078
Strategies and performance of the CMS silicon tracker alignment during LHC Run 2
Tumasyan, A., Adam, W., Andrejkovic, J. W., Bergauer, T., Blöch, D., Chatterjee, S., … Vetens, W. (2022). Strategies and performance of the CMS silicon tracker alignment during LHC Run 2. Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1037, 166795 (45 pp.). https://doi.org/10.1016/j.nima.2022.166795
 

Pages